Release Notes & Known Issues
Release Notes
CWMS-Vue has now been packaged as its own standalone package that is independent of the traditional HEC-RTS software package. The CWMS-Vue build can be replaced in the CWMS-v3.5 package without impact to anything within the CAVI except for opening the application directly under CAVI Tools→Applications→CWMS-Vue. All the other shortcuts from the CAVI will open the embedded CWMS-Vue (v4.0.1) and will only display the Time Series Tabs.


New Features
Below are the major features and issues that have been addressed since CWMS-Vue v4.0.1.
Performance Improvements
Lazy loading has been implemented for the Ratings Tabs so that additional metadata loads in the background. Additionally, rating curves are only loaded on demand when a rating specification is expanded, rather than loading all rating curves for all rating specifications at load time.
Versioned Time Series (TS) are now loaded on demand when a TS that has versioned TS is expanded rather than having all Versioned TS loaded at catalog load time.
Known Issues
Below is a list of Known Issues and their current status. Issues with a status of Resolved have been addressed and are included in CWMS-Vue 4.1.
| Summary | Component/s | Public Description | Key | Public Status |
|---|---|---|---|---|
| Build Catalog Loading up front takes a long time | Catalog | In CWMS-Vue 3.4, after you connect to a DB, the wait indicator at the bottom on the CWMS-Vue window shows it is loading the catalog. This process takes far too long. | CWMSVUE-674 | Resolved |
| Location group tab does not load using CDA | CWMS Location Groups Tab | Location group tab does not load using CDA | CWMSVUE-694 | Resolved |
| Setting Location Active Field does not save | CWMS Locations Tab, CWMS Time Series Tab | Setting Location Active Field does not save | CWMSVUE-690 | Resolved |
| Make Ratings Specifications and Measurements un-collapsed by default | CWMS Measurements Tab, CWMS Ratings Tab | Make Ratings Specifications and Measurements un-collapsed by default | CWMSVUE-587 | Resolved |
| Exception when creating Rating Specification | CWMS Ratings Tab | If the user attempts to create a new Rating Spec without first adjusting the selection for Rating Template, the Parameters box on the New Rating Specification form is blank. Attempting to save the Rating Spec throws an exception. | CWMSVUE-624 | Resolved |
| Issue with Ratings for Base Locations longer than 16 characters | CWMS Ratings Tab | When trying to create a new rating spec, location IDs with base locations longer than 16 characters fail to display. | CWMSVUE-656 | Resolved |
| Time Series Groups Category do not display description | CWMS Time Series Groups Tab | Time Series Groups Categories do not display a description, if one is entered. The user may enter a description and save, but after refresh of catalog, the description is not displayed. | CWMSVUE-620 | Resolved |
| Timeseries lazy loading freezes when version timeseries loaded | CWMS Time Series Tab | When timeseries tab is loaded it will be accessible originally after initial catalog load. During the Lazy load process when the Timeseries extents are loaded and the versioned timeseries the timeseries tab and all of CWMS-Vue will freeze until all versioned timeseries are available. This can be 2 minutes or it can be 10 minutes depending on the number of versioned time series being loaded. | CWMSVUE-693 | Resolved |
| Replace CMA within CWMS-Vue | CMA | Replacement for CMA. | CWMSVUE-589 | In Progress |
| Allow user to edit location Kind parameter | CMA, CWMS Locations Tab | As part of the migration away from CMA, allow users to edit the location kind parameter both when creating a new location and when updating an existing location. | CWMSVUE-635 | In Progress |
| Exception when trying to plot large time windows in Measurements tab using CDA | CDA, Measurement Plots | Exception when trying to plot large time windows in Measurements tab using CDA. Current workaround is to limit time window to ~5yrs. | CWMSVUE-636 | Future Version |
| Add filter by Watershed and Stream to Time Series Tab | CMA, CWMS Time Series Tab | Add a filter by watershed and/or stream to the the Time Series tab. | CWMSVUE-646 | Future Version |
| Add or Migrate Basin Connectivity Editors | CMA | Migrate the basin connectivity editors from REGI, or create editors for the basin connectivity. This will enable defining streams and watersheds for filtering locations and time series by stream or watershed. | CWMSVUE-710 | Future Version |
| Console still shows “CWMSVue 4.0.0” in the title bar | Code Debt, Technical Debt | Console window title is not updated with current CWMS-Vue build name/number. | CWMSVUE-731 | Future Version |
| Agency Alias Location Groups not showing up in Ratings Tab | Code Debt, Technical Debt | The agency alias information does populate in the Ratings Tab. | CWMSVUE-732 | Future Version |
| Location Level Editor - Add Ability to put expiration date into current GUI | CWMS Location Levels Tab | Add ability to put expiration date for into Location Level Editor | CWMSVUE-338 | Future Version |
| Rating Curve filter column resets after lazy loading completes | CWMS Ratings Tab | Rating Curve filter column resets once lazy loading is complete. The reset goes back to what was set when CWMS-Vue was opened (likely blank). | CWMSVUE-735 | Future Version |
| Filter resets in Time Series Tab after lazy loading completes | CWMS Time Series Tab | Time Series Id filter column resets once lazy loading is complete. The reset goes back to what was set when CWMS-Vue was opened (likely blank). | CWMSVUE-734 | Future Version |
| CWMSVue JavaFX warning of unnamed module | General | CWMS-Vue JavaFX warning of unnamed module CAVI Warning WARNING: Unsupported JavaFX configuration: classes were loaded from 'unnamed module @6ce139a4' CWMS-Vue Warning WARNING: Unsupported JavaFX configuration: classes were loaded from 'unnamed module @78e01b3d' | CWMSVUE-698 | Future Version |
| Vertical Datum Unit Label Incorrect | Vertical Datum | The "Vertical Datum Units" is mislabeled as meters versus feet. This issue is cosmetic only; the data itself is in the correct units as specified in the View-->Unit System. | CWMSVUE-717 | Future Version |