Keyword | Function | Values |
* (asterisk) | Identifies comment line. |
|
ENDFILE | Lines following this keyword will be ignored. |
|
TimeStart | Sets beginning time of first interpolation interval | Valid HECTime strings for date and time Example: 13JAN1995, 1100 |
TimeEnd | Sets ending time of last interpolation interval | Valid HECTime strings for date and time |
TimeStep | Sets length of grid time interval | Numerical values in minutes. Acceptable values are limited to 1, 5, 10, 15, 20, 30, 60, 120, 180, 240, 360, 480, 720, 1440. Defaults to 60 minutes. |
Weight | Ignored keyword in HEC-MetVue |
|
| Range for extrapolation | Range in meters radially from the Convex Hull of the gage network, to which extrapolation is allowed. Default is 30,000m. Cannot be used with -noExtrapolate command line argument. Note that UNLIMITED argument in GageInterp is not supported in GageToTin. |
AdjustMethod | Sets the adjustment method (BIAS or LAPSE) to be applied to the output grids | BIAS can be used for most data types, including precipitation. LAPSE can be used for temperatures only. |
AdjustGridFile | DSS file containing the bias or elevation grid | DSS filename. |
AdjustGridPath | Identifies DSS grid record containing bias factors or elevations for lapse | DSS pathname. Any values in BIAS grids are acceptable. Elevation grids must be in meters. |
LapseMethod | Sets method for calculating lapse rate | FIXED, , or |
| Sets constant lapse rate | Lapse rate in degrees C per m. |
LapseRateFile | Sets name of DSS file containing a time series of lapse rates | Name of existing DSS file containing the lapse rate time series. |
LapseRatePath | Sets the path of the DSS record containing a time series of lapse rates. | Path name of an existing time series record containing lapse rates expressed in deg F/FT or deg C/m |