To link the model alternatives, complete the following:
- From the HEC-RTS main window, click the Setup tab, from the Models menu, click Model Linking, the Model Linking Editor will open.
- Select the Forecast Run you wish to configure in the Forecast Run list (Example Linking).
- Select the first model alternative in the Model Requiring Input list (Example Linking).
- In the Model Linking Editor table (Example Linking), specify the Input From for each row as either a model alternative or Extract List.
- For each row that has a model alternative selected in the Input From column, HEC-RTS has compiled a list of locations and parameters for the selected model alternative. To specify the Location/Parameter there are two ways, from the Location/Parameters cell, from the list, select the correct parameter. Another way to select the correct Location/Parameters, click Browse, the Select Source Data Location dialog will open (Model Linking Editor Overview).
- Repeat steps 3 through 5 for each model alternative in the Model Requiring Input list (Example Linking).
- Repeat all steps for each Forecast Run you wish to configure.
- When you are finished with model linking, from the Modeling Linking Editor (Example Linking), click OK. The Modeling Linking Editor will close, and all changes will be saved.