Outlets typically represent structures near the bottom of the dam that allow water to exit in a controlled manner. They are often called gravity outlets because they can only move water when the head in the reservoir is greater than the head in the tailwater. Up to ten independent outlets can be included in the reservoir.

Culvert Outlet

The culvert outlet can handle may flow types including pressure flow, so it allows for partially full or submerged flow through a culvert with a variety of cross-sectional shapes. Culvert flow calculations can be complicated, but the approach taken by HEC-HMS is shared with RAS – it simplifies the analysis by considering the flow either Inlet Control or Outlet Control. As described in Chapter 6 of the HEC-RAS Technical Reference Manual, "Inlet control flow occurs when the flow capacity of the culvert entrance is less than the flow capacity of the culvert barrel. The control section of a culvert operating under inlet control is located just inside the entrance of the culvert. The water surface passes through critical depth at or near this location, and the flow regime immediately downstream is supercritical. For inlet control, the required upstream energy is computed by assuming that the culvert inlet acts as a sluice gate or as a weir. Therefore, the inlet control capacity depends primarily on the geometry of the culvert entrance. Outlet control flow occurs when the culvert flow capacity is limited by downstream conditions (high tailwater) or by the flow carrying capacity of the culvert barrel. The HEC RAS culvert routines compute the upstream energy required to produce a given flow rate through the culvert for inlet control conditions and for outlet control conditions. In general, the higher upstream energy "controls" and determines the type of flow in the culvert for a given flow rate and tailwater condition. For outlet control, the required upstream energy is computed by performing an energy balance from the downstream section to the upstream section. The HEC RAS culvert routines consider entrance losses, friction losses in the culvert barrel, and exit losses at the outlet in computing the outlet control headwater of the culvert."
HEC-HMS shares the RAS culvert routines, and thus requires the same input data. RAS, however, assumes a roadway crest, whereas HEC-HMS does not. Figure XXX depicts the relationships between upstream energy and flow rate for outlet control and inlet control flows.



Thus, there are three different solution methods for culvert outlets, allowing for Inlet Control, Outlet Control, or Automatic. Automatic allows the program to determine whether the flow is inlet or outlet controlled at each timestep. This approach is highly recommended, unless the user is modeling a special case.
Table 2.Culvert Outlet Settings

Settings

Options

Direction


Number of Barrels

Select up to 10 identical barrels

Solution Method

Automatic, Inlet Control, Outlet control

Shape

Circular, Semi-Circular, Elliptical, Arch, High Profile Arch, Low Profile Arch, Pipe Arch, Box, Con Span


Depending on which shape you select, you have a subset of Charts and Scales to choose from. (big list)

Settings

Length, Rise, {Span}, Inlet Elevation, Entrance Coefficient, Outlet Elevation, Exit Coefficient, Manning's n.


The limitations to the culvert calculations are that no upstream or downstream cross sections are used. So the energy gradeline is calculated assuming a quiescent, level pool above the inlet and a quiescent stilling basin at the outlet.

Inlet Controlled
Use this method when the culvert outflow is controlled by a high pool elevation in the reservoir. See equations 6-2 and 6-3 in the RAS Tech Ref Man for the calculations used. HEC-HMS departs from the RAS approach at the Outlet Controlled Headwater. Equation 6-4 is modified for HEC-HMS so that the velocities are assumed zero. The same is true for equation 6-7.

Outlet Controlled

Outlet controlled calculation can handle zero, partial, pressurized flow. It changes based on the shape of the culvert. Culvert outflow that is controlled by a high tailwater condition uses this

Automatic
In order to determine which type of flow rules, energy minimization is performed. Flow is computed using inlet or outlet control and the lower flow is chosen.

Outlet Shape

You must specify the outlet shape and related parameters so that the HEC-HMS can use the appropriate equations. Table XXX shows a list of the outlet cross section shapes and the associated parameters used in the calculations.

Table 3.Listing of which parameters are required for each cross section shape.

Cross Section Shape

Diameter

Rise

Span

Circular

X



Semi Circular

X



Elliptical


X

X

Arch


X

X

High-Profile Arch



X

Low-Profile Arch



X

Pipe Arch


X

X

Box


X

X

Con Span


X

X

Orifice Outlet

The orifice outlet assumes a large outlet with sufficient submergence for orifice flow conditions to dominate. It should not be used to represent an outlet that may flow only partially full. The necessary submergence is typically present for low level reservoir outlets, but it may not be assured for small reservoirs, such as those on farms. If there is any uncertainty about whether or not the large orifice approach is appropriate, it is best to use the Culvert approach instead. The downside is that it may take ten to twenty times longer to calculate.

In order to ensure that the outlet is experiencing pressure flow conditions, the inlet of the structure should be submerged at all times by a depth at least 0.2 times the height of the orifice outlet. The approximate height is estimated to be the square root of the area. The water elevation is calculated and compared accordingly. HEC-HMS will check this condition and return and error messages with the number of times the condition was not met.

Table 4.Orifice Outlet Settings

Settings

Options

Direction

Main or auxiliary

Number of Barrels

You must select up to 10 identical barrels

Center Elevation

center of the cross-sectional flow area

Area

cross-sectional flow area

Coefficient

dimensionless discharge coefficient

The center elevation specifies the center of the cross-sectional flow area. It is used to compute the head on the outlet, so no flow will be released until the reservoir pool elevation is above this specified elevation. The cross-sectional flow area of the outlet must be specified. The orifice assumptions are independent of the shape of the flow area. The dimensionless discharge coefficient must be entered. This parameter describes the energy loss as water exits the reservoir through the outlet.

Section 6 of the HEC-RAS Technical Reference Manual includes detailed descriptions and equations used in culvert hydraulics and flow analysis. Since much of the approach is shared with HEC-HMS, these descriptions are not repeated here. Refer to the HEC-RAS manual for details on the algorithms. Note that the difference between the HEC-RAS and the HEC-HMS outlet flow calculations is that HEC-HMS does not consider flow in upstream or downstream cross sections, thus the equations are simplified by assuming zero velocity.