Introduction > General Concepts for HEC-DSS


Time Series Conventions

This section covers the conventions for both regular-interval and irregular-interval time series data. There are four data "types" recognized by the DSS.

 

They are:

 

Data Type Example
PER-AVER Monthly Flow
PER-CUM Incremental Precipitation
INST-VAL Stages
INST-CUM Precipitation Mass Curve

 

Both regular and irregular interval time series record pathnames have the same A, B, C, and F parts. Data blocks are labeled with a six part pathname. The parts are referenced by the characters A, B, C, D, E, and F, and are separated by a slash "/", so that a pathname would look as follows:

/A/B/C/D/E/F/

The conventions for the part labels are:

 

Part A – Group

 

Part A describes the general group of the data. It may be a watershed name, a study name, etc. that would cause all associated records to be recognized as a group. This part is not required.

 

Part B - Location

 

Part B is the basic location identifier of the data, generally the site name.  A similar identifier, such as a project ID, USGS gage ID, or NWS station ID may be used.  This part is required.

 

When a hydrograph is routed from one location to another, the recommended part B is LOC1.LOC2, where LOC1 is the identifier to which the flows are routed, and LOC2 is an identifier for the location from which flows are routed. The second location (.LOC2) is optional.  For example, it may be left out in situations where there is only one routed hydrograph for a location.

 

Part C – Parameter

 

Part C identifies the basic data parameter. A dash is used as a sub separator if further identification is needed. Additional information about the parameter, such as how it was obtained (e.g. "OBSERVED"), should be given in part F. Examples of valid parameters are:

 

FLOW
ELEV
PH
PRECIP-INC
STAGE
TEMP-AIR
TEMP-WATER

 

Recommended C-parts for flows associated with stream locations are as follows:

 

Part C Description
FLOW Total flow
FLOW-LOC Local flow; that is, flow generated only from the subbasin that has an outlet at the specified location.
FLOW-CUM LOC Cumulative local flow. This is the flow from all subbasins downstream from the nearest upstream reservoirs.
FLOW-COMB Combined flow. This is the total flow minus the local flow.
FLOW-DIVERT Flow diverted out of the river at this location
FLOW-mod mod is a user-specified modifier for the flow. For example, FLOW-POWER, to designate a hydrograph from a power plant. Also, FLOW-IN1 for a component of reservoir inflow.
FLOW-IN Reservoir inflow.
FLOW-OUT Reservoir outflow.
ELEV-RES Reservoir elevation.
STORAGE Reservoir storage.

 

Part D - Block Start Date

 

Part D identifies the starting date of the data block. It is described for regular-interval and irregular-interval data in the sections that follow.

 

Part E - Time Interval or Block Length

 

Part E defines the time interval for regular-interval data, or the block length for irregular-interval data. It is further described in the sections that follow.

 

Part F – Descriptor

 

Part F is used to provide any additional information about the data. Its use may vary from application to application as appropriate, and may contain several additional qualifying pieces of information separated by a dash "-". If several forms of data exist, such as OBSERVED or FORECAST, PLAN A or TEST 2, etc. they may be reflected in part F. Generally, the order of multi-descriptors of Part F should be from most to least significant.

 

More: