Repgen 4 (and before) deprecated

The version of repgen distributed with CWMS 3.2.3 has a known issue with _____.   It will not be fixed.   Please contact HEC for assistance with workarounds.   Note that this old version of Repgen will be retired in upcoming versions of CWMS.  

Retired Programs

The COrps of Engineers EDitor (coed) was removed as of CWMS 3.2.2 in favor of newer software.   Admins may need to update any old processes that still rely on coed.    HEC or others within WMCoP can assist with updating such references.   If that is not practical then an office can copy coed from an older version of CWMS to its own 'cwp' user and continue to use it as unsupported.  The old xwindow server version of RiverWare was removed because it no longer functions.    The full list is here: Retired Programs.    

Warning about parameters_units.def

Scripts on the server may show warnings that include a stack trace regarding the absence of $CWMS_HOME/config/db/definitions/parameters_units.def.   This file allows customized definitions on a system.  Since default definitions are built into CWMS, absence of the file is not a problem (unless your office actually requires custom definitions).   

INFO: Reading parameter resource file from file system: {} Apr 12, 2021 2:07:05 PM hec.data.ResourceFileParameterLoader validate
WARNING: Error reading parameter resource file input stream
java.io.FileNotFoundException: /wm/xxx/yyyyyyy/config/db/definitions/parameters_units.def (No such file or directory)
        at java.io.FileInputStream.open0(Native Method)
        at java.io.FileInputStream.open(FileInputStream.java:195)

        . . . 

The ugly logging will be remedied in a future version.

ProcessSHEFIT Issues

CWMS 3.2.3 has resolved issues with ProcessSHEFIT running out of database connections. Pl. contact HEC if you still notice this issue.

Database

Schema version

HEC would like to ensure CWMS 3.2.3 test sites are running Schema version 18.1.8 or higher 

Password Problems with Oracle Accounts

CWMS 3.2.3 has resolved several issues related to invalid username/password messages as well as user accounts getting locked. If you still see  "sql.SQLException: ORA-01017: invalid username/password; logon denied" or "ORA-28000: the account is locked" in CWMS client console logs or in CWMS server logs, report them to HEC.