To complete the configuration of a model alternative, you must assign each model alternative a Model Alternative Key. The Model Alternative Key is an alpha-numeric identifier that will determine the names of your forecast runs.

To assign model alternative keys:

  1. Within the Setup module, select Model Alternative Keys from the Models menu. The Model Alternative Keys dialog will open.
    Model Alternative Keys
  2. Using the Plugin drop-down list, select the model for which you wish to assign a key.
  3. In the Key field, enter a single unique alpha-numeric character that will be used to identify the listed Model Alternative.
  4. Repeat Steps 2 and 3 for all models and model alternatives.
  5. Click OK, and the Model Alternative Keys dialog will close.
In the above figure, only one alternative has been assigned a key. The first two alternatives do not have keys, and a model alternative key can be assigned if needed. A key has been previously assigned for the third alternative and cannot be modified.

Model alternatives for the standard programs in CWMS might be named similar to the following:

Example Model Alternatives for MFP

ID

Name

N

No future precipitation

2

2-inches future precipitation

4

4-inches future precipitation

Q

QPF

R

One-half QPF

S

Twice QPF


Example Model Alternatives for HEC-MetVue

ID

Name

N

No future precipitation

2

2-inches future precipitation

4

4-inches future precipitation

Q

QPF

R

One-half QPF

S

Twice QPF


Example Model Alternatives for HEC-HMS

ID

Name

N

Normal conditions

W

Wet basin conditions

D

Dry basin conditions


Example Model Alternatives for HEC-ResSim

ID

Name

N

Normal operations

R

Restricted downstream channel capacity

W

White water release schedule

S

Fish spawning release schedule


Example Model Alternatives for HEC-RAS

ID

Name

N

Normal river conditions

H

High channel roughness

L

Low channel roughness

B

Bridge out


Example Model Alternatives for HEC-FIA

ID

Name

N

Normal conditions

E