Issue | Description | Status 1 2 3 4
|
---|
Reference Lines - 1D Only crash
| Reference lines are not allowed in a 1D only model. A runtime crash will ensue for models that have 1D elements only and Reference Lines. | |
2D Bridge Curves Being Recomputed for Each Simulation | The rating curves for 2D bridges are unnecessarily being recomputed upon each simulation run. | |
Can't Complete Geometry When Number of Pump Stations Exceed Number of Structures of Any Type | If there are more pump stations in the model domain than total structures (inline, lateral, SA/2D, bridges) geometry property tables will not be able to complete, preventing a model compute. Workaround: Add dummy internal SA/2D structures until total number of structure equals or exceeds the number of pump stations. | |
Observed Data for Reference Points Not Plotting
| Reference Points with Observed Data are not plotting in the hydrograph plot. (Version 6.2 is correctly plotting observed data.)
| |
Observed Data for Reference Lines Not Plotting
| Reference Lines with Observed Data are not plotting in the hydrograph plot. (Version 6.2 is correctly plotting observed data.)
| |
Observed Data for Cross Sections Not Plotting
| Cross Sections with Observed Data are not plotting in the hydrograph plot.
| |