NEW IN RESSIM 4.0 The edit panel for the Reverse Water Account Yield analysis type is shown in "Figure: Yield Analysis Tab – Reverse Water Account Yield View". The process for setting up a Reverse Water Account Yield analysisproceeds from the top down in the edit panel.
Figure: Yield Analysis Tab – Reverse Water Account Yield View
Select Water Account—Select the water account for which you want to compute the maximum storage. In order for there to be anything in the list to choose from, you must have—1) created a Water Account Set with at least one water account in it, and 2) selected that water account set on the operations tab of this yield alternative. See "Selecting a Water Account Set" for further details.
Figure: Reverse Water Account Yield – Edit Adjustment Options
Adjustment Limits—There are two options available to adjust the pool limits:
% of Con.
Constant
Adjacent Zone Adjustments— There are two options available for adjacent zone adjustments:
Collapse Zones
Proportionally Scale
Demand Rules—this table gets loaded with all the rules that are associated with the reservoir selected in section1.
Maximum Iterations—this is maximum number of iterations that the yield analysis may perform in its attempt to converge on a solution. The default value is 25.
Convergence Method—this radio button provides the choice of either Bisection Search Only or Heuristic and Bisection Search. See the previous section for a detailed description.